FXS Blade Service Alarm

This alarm is applicable only to MP-1288.

acModuleServiceAlarm

Alarm

acModuleServiceAlarm

OID

1.3.6.1.4.1.5003.9.10.1.21.2.0.122

Description

The alarm is sent due to a hardware failure on the FXS blade, due to the following:

Multiple FXS ports are out-of-service (due to high temperature, Serial Peripheral Interface or electrical shortage).
DSP failure (due to high temperature), causing FXS ports to go out-of-service.

Alarm Source

Chassis/Module# (Analog)

Event Type

equipmentAlarm

Probable Cause

equipmentMalfunction

Severity

Condition

Alarm Text

Corrective Action

Major

More than 33% of FXS ports on the FXS blade are out-of-service.
Hardware failure (DSP) on the FXS blade. If the fault is due to exceeding the high temperature limit, all FXS ports on this blade are out-of-service.

"Multiple FXS ports are Out-Of-Service"

Service the faulty blade.

If the alarm is sent as a result of a high DSP temperature, you must cold restart the device (power off and then power on) to return the blade to service.

Minor

More than five FXS ports but less than 33% of FXS ports are out-of-service on the FXS blade.

Major to Minor: Less than 25% of FXS ports are out-of-service on the FXS blade.

"Multiple FXS ports are Out-Of-Service"

Service the faulty blade.

Clear

Less than 4 FXS ports are out-of-service on the FXS blade.

-

-